WBX Receiver Performance Plots
User documentation
01/15/2010
IIP2, IIP3, and Noise Figure Plots vs. Frequency and Gain
Conditions
- IIP3 and IIP2
- Tone 1: -30dBm, 570KHz
- Tone 2: -30dBm, 770KHz
- NF:
- Reference Tone: -100dBm, 570KHz
Notes
From these plots you can see that:
- The minimum noise figure over the whole band is 5-6 dB
- Typical IIP3 is 5-10 dBm
- Typical IIP2 is 40-55 dBm
At every frequency there is a gain setting which gives a noise figure of less than 8 dB while simultaneously giving an IIP3 of better than 0dBm and an IIP2 of better than 40 dBm.